Nissan Juke Service and Repair Manual : Auto retractable door mirror does not operate
Diagnosis Procedure
1.CHECK INTELLIGENT KEY AND DOOR REQUEST SWITCH OPERATION
Check operation of Intelligent Key and door request switch.
Is the inspection result normal? YES >> GO TO 2.
NO >> Repair or replace the malfunctioning parts.
2.CHECK DOOR MIRROR (OPEN/CLOSE MOTOR) CIRCUIT
Check door mirror (open/close motor) circuit.
Refer to MIR-25, "Component Function Check".
Is the inspection result normal? YES >> GO TO 3.
NO >> Repair or replace the malfunctioning parts.
3.CHECK AUTO RETRACTABLE DOOR MIRROR CIRCUIT
Check auto retractable door mirror circuit.
Refer to MIR-30, "Component Function Check".
Is the inspection result normal? YES >> GO TO 4.
NO >> Repair or replace the malfunctioning parts.
4.CONFIRM THE OPERATION
Confirm the operation again.
Is the inspection result normal? YES >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".
NO >> GO TO 1.
Electric foldable door mirror does not operate
Diagnosis Procedure
1.CHECK DOOR MIRROR (OPEN/CLOSE MOTOR) CIRCUIT
Check door mirror (open/close motor) circuit.
Refer to MIR-25, "Component Function Check".
Is the inspection result ...
Squeak and rattle trouble diagnoses
Work Flow
CUSTOMER INTERVIEW
Interview the customer if possible, to determine the conditions that exist
when the noise occurs. Use the Diagnostic
Worksheet during the interview to document the ...
Other materials:
Horn function
Component Function Check
1.CHECK FUNCTION 1
1. Disconnect vehicle security horn relay.
2. Perform “VEHICLE SECURITY HORN” in “ACTIVE TEST” mode of “THEFT ALM” of “BCM”
using CONSULT-
III.
3. Check the horn operation.
Is the operation normal?
YES >> GO TO 2.
NO >> Go to SE ...
C1105, C1106, C1107, C1108 wheel sensor
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If “DTC CONFIRMATION PROCEDURE” has been previously conducted, always turn
ignition switch OFF and
wait at least 10 seconds before conducting the next test.
>> GO TO 2.
2.CHECK DTC DETECTION
With CONSULT-I ...
Test Value and Test Limit
The following is the information specified in Service $06 of ISO 15031-5.
The test value is a parameter used to determine whether a system/circuit
diagnostic test is OK or NG while
being monitored by the ECM during self-diagnosis. The test limit is a reference
value which is specified as the ...