Nissan Juke Service and Repair Manual : P1610 lock mode
Description
ECM forcibly switches to the mode that inhibits engine start, when engine start operation is performed 5 times or more while communication between ECM and BCM is not normal, or when engine start operation is performed 5 times or more using the unregistered ignition key.
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE
1. Turn ignition switch ON.
2. Check DTC in “Self Diagnostic Result” mode of “ENGINE” using CONSULT-III.
Is DTC detected? YES >> Refer to SEC-192, "Diagnosis Procedure".
NO >> INSPECTION END
Diagnosis Procedure
1.CHECK ENGINE START FUNCTION
1. Perform the check for DTC except DTC P1610.
2. Use CONSULT-III to erase DTC after fixing.
3. Turn ignition switch OFF.
4. Turn ignition switch ON using the registered ignition key and wait for 5 seconds.
5. Turn the ignition switch OFF and wait 5 seconds.
6. Repeat steps 4 and 5 twice (a total of 3 times).
7. Check that engine can start using the registered ignition key.
>> INSPECTION END
P1611 ID discord, IMMU-ECM
DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.PERFORM DTC CONFIRMATION PROCEDURE 1. Turn ignition switch ON. 2. Check DTC in “Self Diagnostic Result” mode of “ENGINE” using CONSULT ...Other materials:
High pressure fuel pump
Component Function Check
1.CHECK HIGH PRESSURE FUEL PUMP FUNCTION
With CONSULT-III
1. Start engine.
2. Check “FUEL PRES SEN V” in “DATA MONITOR” mode of “ENGINE” using CONSULT-III.
Without CONSULT-III
1. Start engine.
2. Check the voltage between ECM harness connector terminals as per the ...
P0471 exhaust gas pressure sensor 1
DTC Logic
DTC DETECTION LOGIC
NOTE:
If DTC P0471 is displayed with DTC P0470 or P2226, first perform trouble
diagnosis for DTC P0470 or P2226.
Refer to EC-944, "DTC Logic" (P0470), EC-1002, "DTC Logic" (P2226).
Diagnosis Procedure
1.CHECK GROUND CONNECTIONS
1. Turn i ...
Interior room lamp control circuit
Description
Controls each interior room lamp (ground side) by PWM signal.
NOTE:
PWM signal control period is approximately 250 Hz (in the gradual
brightening/dimming).
Component Function Check
CAUTION:
Before performing the diagnosis, check that the following are normal.