Nissan Juke Service and Repair Manual : Operation inspection

Work Procedure

The purpose of the operational check is to check that the individual system operates normally.

Check condition : Engine running at normal operating temperature.

1.CHECK BLOWER MOTOR

1. Operate fan control dial.

2. Check that fan speed changes. Check operation for all fan speeds.

Is the inspection result normal? YES >> GO TO 2.

NO >> GO TO 6.

2.CHECK DISCHARGE AIR

1. Operate fan control dial to set the fan speed to maximum speed.

2. Operate MODE dial to each position.

3. Check that air outlets change according to each indicated air outlet by placing a hand in front of the air outlets. Refer to VTL-5, "System Description".

Is the inspection result normal? YES >> GO TO 3.

NO >> GO TO 6.

3.CHECK INTAKE AIR

1. Operate intake lever to each position.

2. Listen to intake sound and confirm air inlets change.

Is the inspection result normal? YES >> GO TO 4.

NO >> GO TO 6.

4.CHECK DISCHARGE AIR TEMPERATURE

1. Operate temperature control dial.

2. Check that discharge air temperature changes.

Is the inspection result normal? YES >> GO TO 5.

NO >> GO TO 6.

5.CHECK TEMPERATURE INCREASE

1. Turn temperature control dial to full hot position.

2. Check that warm air blows from air outlets.

Is the inspection result normal? YES >> INSPECTION END

NO >> GO TO 6.

6.CHECK SELF-DIAGNOSIS WITH CONSULT-III

1. Perform self-diagnosis with CONSULT-III.

2. Check that any DTC is detected.

Is any DTC detected? YES >> Perform trouble diagnosis for the detected DTC.

NO >> Refer to HAC-329, "Symptom Table" and perform the appropriate diagnosis.

    Diagnosis and repair workflow
    Work Flow OVERALL SEQUENCE DETAILED FLOW 1.INTERVIEW FOR MALFUNCTION Interview the symptom to the customer. >> GO TO 2. 2.SYMPTOM CHECK Check the symptom from the customer's informa ...

    DTC/circuit diagnosis
    Blower motor Diagnosis Procedure 1.CHECK SYMPTOM Check symptom (A or B). Which symptom is detected? A >> GO TO 2. B >> GO TO 7. 2.CHECK FUSE 1. Turn ignition switch OFF. 2. ...

    Other materials:

    P range interlock door lock/unlock function does not operate
    Diagnosis Procedure 1.CHECK “AUTOMATIC LOCK/UNLOCK SELECT” SETTING IN “WORK SUPPORT” 1. Select “DOOR LOCK” of “BCM” using CONSULT-III. 2. Select “AUTOMATIC LOCK/UNLOCK SELECT” in “WORK SUPPORT” mode. 3. Check “AUTOMATIC LOCK/UNLOCK SELECT” setting in “WORK SUPPORT”. Refer to DLK-501, "DO ...

    Inspection
    OIL LEAKAGE Make sure that gear oil is not leaking from transaxle or around it. OIL LEVEL 1. Remove filler plug (1) and gasket from transaxle case. 2. Check the oil level from filler plug mounting hole as shown in the figure. CAUTION: Never start engine while checking oil level. 3. Set a ...

    Symptom diagnosis
    SYSTEM SYMPTOM Symptom Table The diagnostics item numbers show the sequence for inspection. Inspect in order from item 1. ...