Nissan Juke Service and Repair Manual : Hazard function

Component Function Check

1.CHECK FUNCTION

1. Select “INTELLIGENT KEY” of “BCM” using CONSULT-III.

2. Select “FLASHER” in “ACTIVE TEST” mode.

3. Check that the function operates normally according to the following conditions.

Is the inspection result normal?


Is the inspection result normal? YES >> Hazard warning lamp circuit is OK.

NO >> Refer to DLK-261, "Diagnosis Procedure".

Diagnosis Procedure

1.CHECK HAZARD SWITCH CIRCUIT

Refer to EXL-72, "Component Function Check".

Is the inspection result normal? YES >> GO TO 2.

NO >> Repair or replace the malfunctioning parts.

2.CHECK INTERMITTENT INCIDENT

Refer to GI-42, "Intermittent Incident".

>> INSPECTION END

    Door switch
    Component Function Check 1.CHECK FUNCTION 1. Select “DOOR LOCK” of “BCM” using CONSULT-III. 2. Select “DOOR SW-DR”, “DOOR SW-AS”, “DOOR SW-RL”, “DOOR SW-RR”, “DOOR SW-BK” in “DATA MONITOR” mode. ...

    Intelligent key
    Component Function Check 1.CHECK FUNCTION 1. Select “INTELLIGENT KEY” of “BCM” using CONSULT-III. 2. Select “RKE OPE COUN1” in “DATA MONITOR” mode. 3. Check that the function operates normally acc ...

    Other materials:

    Liquid Gasket
    REMOVAL OF LIQUID GASKET SEALING • After removing mounting nuts and bolts, separate the mating surface using the seal cutter [SST: KV10111100] (A) and remove old liquid gasket sealing. CAUTION: Be careful not to damage the mating surfaces. • Tap the seal cutter [SST: KV10111100] to insert it ...

    Front drive shaft boot
    Exploded View LEFT SIDE 1. Circular clip 2. Dust shield 3. Housing assembly 4. Boot band 5. Boot 6. Damper band 7. Dynamic damper 8. Circular clip 9. Joint sub-assembly : Wheel side : Fill NISSAN Genuine grease or equivalent. : Always replace after every disassembly. RIGHT ...

    P1643 thermoplunger control unit
    DTC Logic DTC DETECTION LOGIC Diagnosis Procedure 1.CHECK THERMOPLUNGER CONTROL UNIT POWER SUPPLY CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect thermoplunger control unit harness connector. 3. Check the voltage between thermoplunger control unit harness connector and ground. Is the ...