Nissan Juke Service and Repair Manual : Auto door lock operation does not operate
Diagnosis Procedure
1.CHECK “AUTO LOCK SET” SETTING WITH CONSULT-III
1. Select “MULTI REMOTE ENT” of “BCM” using CONSULT-III.
2. Select “AUTO LOCK SET” in “WORK SUPPORT” mode.
3. Check “AUTO LOCK SET” in “WORK SUPPORT”.
Refer to DLK-502, "MULTI REMOTE ENT : CONSULT-III Function (BCM - MULTI REMOTE ENT) (Without Super Lock)".
Is the inspection result normal? YES >> GO TO 2.
NO >> Set “AUTO LOCK SET” in “WORK SUPPORT”.
2.REPLACE BCM
1. Replace BCM. Refer to BCS-161, "Removal and Installation".
2. Confirm the operation after replacement.
Is the result normal? YES >> INSPECTION END
NO >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".
P range interlock door lock/unlock function does not operate
Diagnosis Procedure 1.CHECK “AUTOMATIC LOCK/UNLOCK SELECT” SETTING IN “WORK SUPPORT” 1. Select “DOOR LOCK” of “BCM” using CONSULT-III. 2. Select “AUTOMATIC LOCK/UNLOCK SELECT” in “WORK SUPPORT” mod ...Unlock link function does not operate
Diagnosis Procedure 1.REPLACE BCM • Replace BCM. Refer to BCS-161, "Removal and Installation". • Confirm the operation after replacement. Is the result normal? YES >> INSPECTION ...Other materials:
Front wiper motor lo circuit
Component Function Check
1.CHECK FRONT WIPER LO OPERATION
CONSULT-III ACTIVE TEST
1. Select “FRONT WIPER” of IPDM E/R active test item.
2. With operating the test item, check front wiper operation.
Lo : Front wiper (LO) operation
Off : Stop the front wiper.
Is front wiper (LO) operation norma ...
C1176 stop lamp SW2
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If “DTC CONFIRMATION PROCEDURE” has been previously conducted, always turn
ignition switch OFF and
wait at least 10 seconds before conducting the next test.
>> GO TO 2.
2.CHECK DTC DETECTION
With CONSULT ...
P1225 TP sensor
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always turn
ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following proced ...