Nissan Juke Service and Repair Manual : Thermo control amplifier
Removal and Installation
REMOVAL
1. Remove evaporator.
• Refer to HA-55, "EVAPORATOR : Removal and Installation". (HR16DE) • Refer to HA-115, "EVAPORATOR : Removal and Installation". (MR16DDT)
2. Remove the thermo control amp. from evaporator.
INSTALLATION
Note the following items, and then install in the reverse order of removal.
CAUTION:
• Replace O-ring with new one. Then apply compressor oil to them when
installing.
• When install the thermo control amp., set the same position before replacement.
• When remove the thermo control amp., never turn the bracket which is equipped the top of the thermo control amp.
• Check for the leakages when recharging refrigerant. Refer to HA-19, "Leak Test". (HR16DE) or HA-74, "Leak Test". (MR16DDT)
A/C control
Exploded View 1. Intake door cable 2. Air mix door cable 3. Mode door cable 4. A/C control 5. Intake door lever knob A. To intake door link B. To air mix door link C. To mode door link ...Refrigerant pressure sensor
Exploded View Refer to HA-39, "Exploded View". (HR16DE) Refer to HA-94, "Exploded View". (MR16DDT) Removal and Installation REMOVAL Remove refrigerant pressure sensor. Refe ...Other materials:
Sill cover
Exploded View
1. Screw grommet
2. Screw grommet
3. Sill cover
4. Wind defle
Removal and Installation
REMOVAL
1. Remove sill cover front end fixing screw (A).
2. Remove sill cover rear end fixing screw (A).
3. Remove sill cover lower side fixing screws.
4. Fully open front door and ...
P0226 APP sensor
DTC Logic
DTC DETECTION LOGIC
Diagnosis Procedure
1.CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Check ground connection E38. Refer to Ground inspection in GI-44, "Circuit
Inspection".
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or ...
Lubricant
Description
MAINTENANCE OF LUBRICANT LEVEL
The compressor lubricant is circulating in the system together with the
refrigerant. It is necessary to fill compressor
with lubricant when replacing A/C system parts or when a large amount of
refrigerant leakage is
detected. It is important to alwa ...