Nissan Juke Service and Repair Manual : Thermo control amplifier

Removal and Installation

REMOVAL

1. Remove evaporator. Refer to HA-115, "EVAPORATOR : Removal and Installation".

2. Remove thermo control amp. from evaporator.

INSTALLATION

Note the following items, and then install in the reverse order of removal.

CAUTION:
• Replace O-ring with new one. Then apply compressor oil to them when installing.

• When install the thermo control amp., set the same position before replacement.

• When remove the thermo control amp., never turn the bracket which is equipped the top of the thermo control amp.

• Check for the leakages when recharging refrigerant. Refer to HA-74, "Leak Test".

    A/C control
    Exploded View 1. Intake door cable 2. Mode door cable 3. A/C control 4. Air mix door cable 5. Intake door lever knob A. To mode door link B. To intake door link C. To air mix door link ...

    Refrigerant pressure sensor
    Exploded View Refer to HA-94, "Exploded View". Removal and Installation REMOVAL Refer to HA-96, "REFRIGERANT PRESSURE SENSOR : Removal and Installation". INSTALLATION Insta ...

    Other materials:

    Front wiper drive assembly
    Exploded View REMOVAL LHD models 1. Front wiper arm cap 2. Front wiper arm LH 3. Front wiper blade LH 4. Front wiper arm RH 5. Front wiper blade RH 6. Front wiper drive assembly : Pawl : N·m (kg-m, in-lb) : N·m (kg-m, ft-lb) RHD models 1. Front wiper arm cap 2. Front wiper arm ...

    Back door does not opened
    Diagnosis Procedure 1.CHECK BACK DOOR OPENER SWITCH Check back door opener switch. Refer to DLK-513, "Component Function Check". Is the inspection result normal? YES >> GO TO 2. NO >> Repair or replace the malfunctioning parts. 2.CHECK BACK DOOR OPENER ACTUATOR ...

    System description
    COMPONENT PARTS Circuit Breaker The PTC thermistor generates heat in response to current flow. The temperature (and resistance) of the thermistor element varies with current flow. Excessive current flow will cause the element's temperature to rise. When the temperature reaches a specified level ...