Nissan Juke Service and Repair Manual : Service

• Never use electrical test equipment to check SRS circuits unless instructed to in this Service Manual.

• Before servicing the SRS, turn ignition switch OFF, disconnect battery negative terminal and wait at least 3 minutes.

For approximately 3 minutes after the battery negative terminal are removed, it is still possible for the air bag and seat belt pre-tensioner to deploy. Therefore, never work on any SRS connectors or wires until at least 3 minutes have elapsed.

• Diagnosis sensor unit must always be installed with their arrow marks “pointing towards the front of the
pointing towards the front of the vehicle for proper operation. Also check diagnosis sensor unit for cracks, deformities or rust before installation and replace as required.

• The spiral cable must be aligned in the neutral position since its rotations are limited. Never turn steering wheel and column after removal of steering gear.

• Handle air bag module carefully. Always place driver and front passenger air bag modules with the pad side facing upward and seat mounted front side air bag module standing with the stud bolt side facing down.

• Conduct self-diagnosis to check entire SRS for proper functioning after replacing any components.

• After air bag inflates, the front instrument panel assembly should be replaced if damaged.

• Always replace instrument panel pad following front passenger air bag deployment.

    Precaution for Disposal
    • Before disposing of air bag module, pop-up roll bar and seat belt pre-tensioner, or vehicles equipped with such systems, deploy the systems. If such systems have already been deployed due to an ...

    Preparation
    Special Service Tool Commercial Service Tools ...

    Other materials:

    Charge air cooler
    Exploded View 1. Air inlet hose 2. Clamp 3. Air inlet tube 4. Air inlet hose 5. Charge air cooler 6. Air inlet hose 7. Air inlet tube 8. Turbocharger 9. Air inlet tube assembly A. 1st step: 5.0 N·m (0.51 kg-m, 44 ft-lb) 2nd step: 7.0 N·m (0.71 kg-m, 62 ftlb) B. Paint mark C. T ...

    Power supply and ground circuit
    Combination meter COMBINATION METER : Diagnosis Procedure 1.CHECK FUSE Check for blown fuses. Is the inspection result normal? YES >> GO TO 2. NO >> Be sure to eliminate cause of malfunction before installing new fuse. 2.CHECK POWER SUPPLY CIRCUIT Check voltage between comb ...

    Service Notice or Precautions for Manual Transaxle
    CAUTION: • Never reuse CSC (Concentric Slave Cylinder). Because CSC slides back to the original position every time when removing transaxle assembly. At this timing, dust on the sliding parts may damage a seal of CSC and may cause clutch fluid leakage. Refer to CL-27, "Removal and Inst ...