Nissan Juke Service and Repair Manual : P range interlock door lock/unlock function does not operate
Diagnosis Procedure
1.CHECK “AUTOMATIC LOCK/UNLOCK SELECT” SETTING IN “WORK SUPPORT”
1. Select “DOOR LOCK” of “BCM” using CONSULT-III.
2. Select “AUTOMATIC LOCK/UNLOCK SELECT” in “WORK SUPPORT” mode.
3. Check “AUTOMATIC LOCK/UNLOCK SELECT” in “WORK SUPPORT”.
Refer to DLK-41, "DOOR LOCK : CONSULT-III Function (BCM - DOOR LOCK) (With Super Lock)".
Is the inspection result normal? YES >> GO TO 2.
NO >> Set “AUTOMATIC LOCK/UNLOCK SELECT” in “WORK SUPPORT”.
2.CHECK “AUTOMATIC DOOR LOCK SELECT” SETTING IN “WORK SUPPORT
”
1. Select “DOOR LOCK” of “BCM” using CONSULT-III.
2. Select “AUTOMATIC DOOR LOCK SELECT” in “WORK SUPPORT” mode.
3. Check “AUTOMATIC DOOR LOCK SELECT” in “WORK SUPPORT”.
Refer to DLK-41, "DOOR LOCK : CONSULT-III Function (BCM - DOOR LOCK) (With Super Lock)".
Is the inspection result normal? YES >> GO TO 3.
NO >> Set “AUTOMATIC DOOR LOCK SELECT” in “WORK SUPPORT”.
3.CHECK “AUTOMATIC DOOR UNLOCK SELECT” SETTING IN “WORK SUPPORT”
1. Select “DOOR LOCK” of “BCM” using CONSULT-III.
2. Select “AUTOMATIC DOOR UNLOCK SELECT” in “WORK SUPPORT” mode.
3. Check “AUTOMATIC DOOR UNLOCK SELECT” in “WORK SUPPORT”.
Refer to DLK-41, "DOOR LOCK : CONSULT-III Function (BCM - DOOR LOCK) (With Super Lock)".
Is the inspection result normal? YES >> GO TO 4.
NO >> Set “AUTOMATIC DOOR UNLOCK SELECT” in “WORK SUPPORT”.
4.REPLACE BCM
1. Replace BCM. Refer to BCS-93, "Removal and Installation".
2. Confirm the operation after replacement.
Is the result normal? YES >> INSPECTION END
NO >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".
IGN off interlock door unlock function does not operate
Diagnosis Procedure
1.CHECK “AUTOMATIC LOCK/UNLOCK SELECT” SETTING IN “WORK SUPPORT”
1. Select “DOOR LOCK” of “BCM” using CONSULT-III.
2. Select “AUTOMATIC LOCK/UNLOCK SELECT” in “WORK SUPPORT” mod ...
Hazard and buzzer reminder does not operate
Diagnosis Procedure
1.CHECK DTC WITH BCM AND COMBINATION METER
Check that DTC is not detected with BCM and combination meter.
Is the inspection result normal?
YES >> GO TO 2.
NO-1 >& ...
Other materials:
B2198 nats antenna AMP.
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE 1
1. Contact Intelligent Key backside to push-button ignition switch.
2. Check DTC in “Self Diagnostic Result” mode of “BCM” using CONSULT-III.
Is DTC detected?
YES >> Go to SEC-65, "D ...
Meter buzzer circuit
Component Function Check
1.CHECK OPERATION OF METER BUZZER
1. Select “BUZZER” of “BCM” on CONSULT-III.
2. Perform “LIGHT WARN ALM” of “Active Test”.
Does meter buzzer beep?
YES >> INSPECTION END
NO >> GO TO 2.
2.CHECK COMBINATION METER INPUT SIGNAL
Select the “Data Monitor” f ...
P0743 torque converter
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
CAUTION:
Be careful of the driving speed.
1.PREPARATION BEFORE OPERATION (PART 1)
If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition
switch OFF and wait for at
least 10 seconds, then perform the next ...