Nissan Juke Service and Repair Manual : P0101 MAF sensor

DTC Logic

DTC DETECTION LOGIC

Diagnosis Procedure


Diagnosis Procedure

1.CHECK AIR FILTER

Check that air filter is not obstructed.

Is the inspection result normal? Yes >> Repair or replace.

No >> GO TO 2.

2.CHECK INTAKE AIR DUCT

Check that intake air duct is not obstructed.

Is the inspection result normal? Yes >> Repair or replace.

No >> GO TO 3.

3.CHECK GROUND CONNECTIONS

1. Turn ignition switch OFF.

2. Check ground connection E38. Refer to Ground inspection in GI-44, "Circuit Inspection".

Is the inspection result normal? YES >> GO TO 4.

NO >> Repair or replace ground connection.

4.CHECK MASS AIR FLOW SENSOR POWER SUPPLY CIRCUIT-I

1. Turn ignition switch OFF.

2. Disconnect mass air flow sensor harness connector.

3. Turn ignition switch ON.

4. Check the voltage between mass air flow sensor harness connector and ground.

Is the inspection result normal?


Is the inspection result normal? YES >> GO TO 6.

NO >> GO TO 5.

5.DETECT MALFANCTIONING PART

Check the following.

• Harness connectors E8, F1 • Harness for open or short between IPDM E/R and mass air flow sensor

>> Repair open circuit or short to ground or short to power in harness or connectors.

6.CHECK MASS AIR FLOW SENSOR GROUND CIRCUIT FOR OPEN AND SHORT

1. Turn ignition switch OFF.

2. Disconnect ECM harness connector.

3. Check the continuity between mass air flow sensor harness connector and ECM harness connector.

4. Also check harness for short to ground and short to power.


4. Also check harness for short to ground and short to power.

Is the inspection result normal? YES >> GO TO 7.

NO >> Repair open circuit or short to ground or short to power in harness or connectors.

7.CHECK MASS AIR FLOW SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT

1. Check the continuity between mass air flow sensor harness connector and ECM harness connector.

2. Also check harness for short to ground and short to power.


2. Also check harness for short to ground and short to power.

Is the inspection result normal? YES >> GO TO 8.

NO >> Repair open circuit or short to ground or short to power in harness or connectors.

8.CHECK MASS AIR FLOW SENSOR

Refer to EC-904, "Component Inspection" Is the inspection result normal? YES >> GO TO 9.

NO >> Replace mass air flow sensor.

9.CHECK INTERMITTENT INCIDENT

Refer to GI-42, "Intermittent Incident", ???INCIDENT SIMULATION TESTS??? and ???GROUND INSPECTION???.

>> INSPECTION END

Component Inspection

1.CHECK MASS AIR FLOW SENSOR

1. Turn ignition switch OFF.

2. Reconnect all harness connectors disconnected.

3. Turn ignition switch ON.

4. Check the voltage between mass air flow sensor harness connector.

Is the inspection result normal?


Is the inspection result normal? YES >> INSPECTION END

NO >> Replace mass air flow sensor.

    P0100 MAF sensor
    DTC Logic DTC DETECTION LOGIC Diagnosis Procedure 1.CHECK GROUND CONNECTIONS 1. Turn ignition switch OFF. 2. Check ground connection E38. Refer to Ground inspection in GI-44, "Circuit In ...

    P0110 IAT sensor
    DTC Logic DTC DETECTION LOGIC Diagnosis Procedure 1.CHECK GROUND CONNECTIONS 1. Turn ignition switch OFF. 2. Check ground connection E38. Refer to Ground inspection in GI-44, "Circuit In ...

    Other materials:

    Child safety
    WARNING Do not allow children to play with the seat belts. Most seating positions are equipped with Automatic Locking Retractor (ALR) mode seat belts. If the seat belt becomes wrapped around a child’s neck with the ALR mode activated, the child can be seriously injured or killed if the seat b ...

    Intelligent Key
    Replace the battery in the Intelligent Key as follows: 1. Remove the mechanical key from the Intelligent Key. 2. Insert a small screwdriver into the slit of the corner and twist it to separate the upper part from the lower part. Use a cloth to protect the casing. 3. Replace the battery with ...

    Back-up lamp switch : Component Inspection
    1.CHECK BACK-UP LAMP SWITCH 1. Disconnect position switch connector. Refer to TM-77, "Removal and Installation". 2. Check continuity between position switch terminals. Is the inspection result normal? YES >> INSPECTION END NO >> Replace position switch. Refer to TM-7 ...