Nissan Juke Service and Repair Manual : P0101 MAF sensor

DTC Logic

DTC DETECTION LOGIC

Diagnosis Procedure


Diagnosis Procedure

1.CHECK AIR FILTER

Check that air filter is not obstructed.

Is the inspection result normal? Yes >> Repair or replace.

No >> GO TO 2.

2.CHECK INTAKE AIR DUCT

Check that intake air duct is not obstructed.

Is the inspection result normal? Yes >> Repair or replace.

No >> GO TO 3.

3.CHECK GROUND CONNECTIONS

1. Turn ignition switch OFF.

2. Check ground connection E38. Refer to Ground inspection in GI-44, "Circuit Inspection".

Is the inspection result normal? YES >> GO TO 4.

NO >> Repair or replace ground connection.

4.CHECK MASS AIR FLOW SENSOR POWER SUPPLY CIRCUIT-I

1. Turn ignition switch OFF.

2. Disconnect mass air flow sensor harness connector.

3. Turn ignition switch ON.

4. Check the voltage between mass air flow sensor harness connector and ground.

Is the inspection result normal?


Is the inspection result normal? YES >> GO TO 6.

NO >> GO TO 5.

5.DETECT MALFANCTIONING PART

Check the following.

• Harness connectors E8, F1 • Harness for open or short between IPDM E/R and mass air flow sensor

>> Repair open circuit or short to ground or short to power in harness or connectors.

6.CHECK MASS AIR FLOW SENSOR GROUND CIRCUIT FOR OPEN AND SHORT

1. Turn ignition switch OFF.

2. Disconnect ECM harness connector.

3. Check the continuity between mass air flow sensor harness connector and ECM harness connector.

4. Also check harness for short to ground and short to power.


4. Also check harness for short to ground and short to power.

Is the inspection result normal? YES >> GO TO 7.

NO >> Repair open circuit or short to ground or short to power in harness or connectors.

7.CHECK MASS AIR FLOW SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT

1. Check the continuity between mass air flow sensor harness connector and ECM harness connector.

2. Also check harness for short to ground and short to power.


2. Also check harness for short to ground and short to power.

Is the inspection result normal? YES >> GO TO 8.

NO >> Repair open circuit or short to ground or short to power in harness or connectors.

8.CHECK MASS AIR FLOW SENSOR

Refer to EC-904, "Component Inspection" Is the inspection result normal? YES >> GO TO 9.

NO >> Replace mass air flow sensor.

9.CHECK INTERMITTENT INCIDENT

Refer to GI-42, "Intermittent Incident", ???INCIDENT SIMULATION TESTS??? and ???GROUND INSPECTION???.

>> INSPECTION END

Component Inspection

1.CHECK MASS AIR FLOW SENSOR

1. Turn ignition switch OFF.

2. Reconnect all harness connectors disconnected.

3. Turn ignition switch ON.

4. Check the voltage between mass air flow sensor harness connector.

Is the inspection result normal?


Is the inspection result normal? YES >> INSPECTION END

NO >> Replace mass air flow sensor.

    P0100 MAF sensor
    DTC Logic DTC DETECTION LOGIC Diagnosis Procedure 1.CHECK GROUND CONNECTIONS 1. Turn ignition switch OFF. 2. Check ground connection E38. Refer to Ground inspection in GI-44, "Circuit In ...

    P0110 IAT sensor
    DTC Logic DTC DETECTION LOGIC Diagnosis Procedure 1.CHECK GROUND CONNECTIONS 1. Turn ignition switch OFF. 2. Check ground connection E38. Refer to Ground inspection in GI-44, "Circuit In ...

    Other materials:

    P1588 G sensor
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE CAUTION: Be careful of the driving speed. 1.PREPARATION BEFORE WORK If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at least 10 seconds, then perform the next test. > ...

    Fuel filler lid opener
    Exploded View 1. Fuel filler lid opener cable 2. Cable protector 3. Fuel filler lid lock assembly 4. Fuel filler lid assembly 5. Spring 6. Bumper rubber : Clip : Do not reuse Fuel filler lid FUEL FILLER LID : Removal and Installation REMOVAL 1. Fully open fuel filler lid. 2. Remov ...

    ESP off switch
    Component Function  Check 1.CHECK ESP OFF SWITCH OPERATION Check that ESP OFF indicator lamp in combination meter turns ON/OFF when ESP OFF switch is operated. Is the inspection result normal? YES >> INSPECTION END NO >> Proceed to diagnosis procedure. Refer to BRC-210, &qu ...