Nissan Juke Service and Repair Manual : Hazard and buzzer reminder does not operate

Diagnosis Procedure

1.CHECK DTC WITH BCM AND COMBINATION METER

Check that DTC is not detected with BCM and combination meter.

Is the inspection result normal? YES >> GO TO 2.

NO-1 >> Refer to BCS-67, "DTC Index". (BCM) NO-2 >> Refer to MWI-36, "DTC Index". (Combination meter) 2.CHECK “HAZARD ANSWER BACK” SETTING IN “WORK SUPPORT”

1. Select “INTELLIGENT KEY” of “BCM” using CONSULT-III.

2. Select “HAZARD ANSWER BACK” in “WORK SUPPORT” mode.

3. Check the “HAZARD ANSWER BACK” in “WORK SUPPORT”.

Refer to DLK-219, "INTELLIGENT KEY : CONSULT-III Function (BCM - INTELLIGENT KEY) (Without Super Lock)".

Is the inspection result normal? YES >> GO TO 3.

NO >> Set “HAZARD ANSWER BACK” in “WORK SUPPORT”.

3.CHECK “ANS BACK I-KEY LOCK” SETTING IN “WORK SUPPORT”

1. Select “INTELLIGENT KEY” of “BCM” using CONSULT-III.

2. Select “ANS BACK I-KEY LOCK” in “WORK SUPPORT” mode.

3. Check the “ANS BACK I-KEY LOCK” in “WORK SUPPORT”.

Refer to DLK-219, "INTELLIGENT KEY : CONSULT-III Function (BCM - INTELLIGENT KEY) (Without Super Lock)".

Is the inspection result normal? YES >> GO TO 4.

NO >> Set “ANS BACK I-KEY LOCK” in “WORK SUPPORT”.

4.CHECK “ANS BACK I-KEY UNLOCK” SETTING IN “WORK SUPPORT”

1. Select “INTELLIGENT KEY” of “BCM” using CONSULT-III.

2. Select “ANS BACK I-KEY UNLOCK” in “WORK SUPPORT” mode.

3. Check the “ANS BACK I-KEY UNLOCK” in “WORK SUPPORT”.

Refer to DLK-219, "INTELLIGENT KEY : CONSULT-III Function (BCM - INTELLIGENT KEY) (Without Super Lock)".

Is the inspection result normal? YES >> GO TO 5.

NO >> Set “ANS BACK I-KEY UNLOCK” in “WORK SUPPORT”.

5.CHECK HAZARD FUNCTION

Check hazard function.

Refer to EXL-72, "Component Function Check".

Is the inspection result normal? YES >> GO TO 6.

NO >> Repair or replace the malfunctioning parts.

6.CHECK INTELLIGENT KEY WARNING BUZZER

Check Intelligent Key warning buzzer.

Refer to DLK-263, "Component Function Check".

Is the inspection result normal? YES >> GO TO 7.

NO >> Repair or replace the malfunctioning parts.

7.REPLACE BCM

1. Replace BCM. Refer to BCS-93, "Removal and Installation".

2. Confirm the operation after replacement.

Is the result normal? YES >> INSPECTION END

NO >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".

    P range interlock door lock/unlock function does not operate
    Diagnosis Procedure 1.CHECK “AUTOMATIC LOCK/UNLOCK SELECT” SETTING IN “WORK SUPPORT” 1. Select “DOOR LOCK” of “BCM” using CONSULT-III. 2. Select “AUTOMATIC LOCK/UNLOCK SELECT” in “WORK SUPPORT” mod ...

    Key reminder function does not operate
    Diagnosis Procedure 1.CHECK DTC WITH BCM Check that DTC is not detected with BCM. Is the inspection result normal? YES >> GO TO 2. NO >> Refer to BCS-67, "DTC Index". ...

    Other materials:

    C1140 actuator relay system
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.PRECONDITIONING If “DTC CONFIRMATION PROCEDURE” has been previously conducted, always turn ignition switch OFF and wait at least 10 seconds before conducting the next test. >> GO TO 2. 2.CHECK DTC DETECTION With CONSULT ...

    Checking bulbs
    With all doors closed, apply the parking brake and place the ignition switch in the ON position without starting the engine. The following lights will come on: , or , , , , , The following lights come on briefly and then go off (if so equipped): , or , , , , , , , , , If ...

    Service Equipment
    RECOVERY/RECYCLING RECHARGING EQUIPMENT Be certain to follow the manufacturer’s instructions for machine operation and machine maintenance. Never introduce any refrigerant other than that specified into the machine. ELECTRICAL LEAK DETECTOR Be certain to follow the manufacturer’s instruction ...