Nissan Juke Service and Repair Manual : Engine idle speed too high

Description

CHART 5: ENGINE IDLE SPEED TOO HIGH

Diagnosis Procedure

1.CHECK ECM POWER SUPPLY AND GROUND CIRCUIT

Check ECM power supply and ground circuit. Refer to EC-885, "Diagnosis Procedure".

Is the inspection result normal? YES >> GO TO 2.

NO >> Repair or replace harness or connector.

2.CHECK WIRING HARNESS

Visually check the condition of the engine wiring harness.

Is the inspection result normal? YES >> GO TO 3.

NO >> Repair or replace harness or connector.

3.CHECK ACCELERATOR PEDAL POSITION SENSOR

Check the accelerator pedal position sensor. Refer to EC-1001, "Component Inspection".

Is the inspection result normal? YES >> INSPECTION END

NO >> Repair or replace.

    Impossible to shut off engine
    Description CHART 4: IMPOSSIBLE TO SHUT OFF ENGINE Diagnosis Procedure 1.CHECK ECM POWER SUPPLY AND GROUND CIRCUIT Check ECM power supply and ground circuit. Refer to EC-885, "Diagnosis Pro ...

    Engine idle speed too low or unstable
    Description CHART 6: ENGINE IDLE SPEED TOO LOW OR UNSTABLE Diagnosis Procedure 1.CHECK FUEL Check that the fuel reservoir is correctly filled and with the right fuel. >> GO TO 2. 2.CHE ...

    Other materials:

    Glow plug
    Exploded View 1. Glow plug Engine front : N·m (kg-m, ft-lb) Removal and Installation REMOVAL CAUTION: Remove glow plug only if necessary. If carbon adheres, it may be stuck and broken. 1. Disconnect the battery cable from the negative terminal. 2. Remove cowl top extension. Refer to EX ...

    Back door lock
    Exploded View 1. Back door lock assembly 2. TORX bolt 3. Back door striker : Do not reuse : N·m (kg-m, ft-lb) : Body grease Door lock DOOR LOCK : Removal and Installation REMOVAL 1. Remove the back door lower finisher. Refer to INT-35, "BACK DOOR LOWER FINISHER : Removal and Instal ...

    P1641 thermoplunger control unit
    DTC Logic DTC DETECTION LOGIC Diagnosis Procedure 1.CHECK THERMOPLUNGER CONTROL UNIT POWER SUPPLY CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect thermoplunger control unit harness connector. 3. Check the voltage between thermoplunger control unit harness connector and ground. Is the ...