Nissan Juke Service and Repair Manual : Both side front fog lamps are not turned on
Description
The front fog lamps are not turned ON in any condition.
Diagnosis Procedure
1.CHECK FUSE
Check that the following fuse is fusing.
Is the inspection result normal? YES >> GO TO 2.
NO >> Repair the applicable circuit. And then replace the fuse.
2.COMBINATION SWITCH INSPECTION
Check combination switch. Refer to BCS-92, "Symptom Table".
Is the inspection result normal? YES >> GO TO 3.
NO >> Repair or replace the malfunctioning part.
3.CHECK FRONT FOG LAMP REQUEST SIGNAL INPUT
CONSULT-III DATA MONITOR
1. Select “FR FOG REQ” of IPDM E/R data monitor item.
2. With operating the front fog lamp switch, check the monitor status.
Is the inspection result normal? YES >> Replace IPDM E/R.
NO >> Replace BCM. Refer to BCS-93, "Removal and Installation" (with Intelligent Key), BCS-161, "Removal and Installation" (without Intelligent Key).
Parking, license plate and tail lamps are not turned on
Without daytime running light system WITHOUT DAYTIME RUNNING LIGHT SYSTEM : Description The parking, license plate, tail lamps and each illumination are not turned ON in any condition. WITHOUT DA ...Other materials:
Condenser
Exploded View
Refer toINT-34, "Exploded View"
Removal and Installation
REMOVAL
1. Remove the back door lower finisher.
Refer to INT-35, "BACK DOOR LOWER FINISHER : Removal and Installation"
2. Remove bolt (A), and then remove condenser (1) from the vehicle
body.
INSTA ...
B26FC key registration
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE
1. Perform initialization of BCM and reregistration of all Intelligent Keys
using CONSULT-III.
For initialization and registration procedures, refer to CONSULT-III Operation
Manual NATS-IVIS/NV ...
ABS warning lamp
Component Function Check
1.CHECK ABS WARNING LAMP FUNCTION
Check that ABS warning lamp in combination meter turns ON for approx. 1
second after ignition switch is
turned ON.
CAUTION:
Never start engine.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Proceed to B ...