DTC Logic

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE


DTC CONFIRMATION PROCEDURE

1.CHECK SELF-DIAG RESULT

1. Turn ignition switch ON.With CONSULT-III


1. Turn ignition switch ON.

2. Perform “Self Diagnostic Result” mode of “AIR BAG” using CONSULT-III.

1. Turn ignition switch ON.Without CONSULT-III


1. Turn ignition switch ON.

2. Check the air bag warning lamp status. Refer to SRC-12, "On Board Diagnosis Function".

NOTE

:

SRS does not enter the diagnosis mode if no malfunction is detected in the user mode.

Is malfunctioning part detected? YES >> Refer to SRC-69, "Diagnosis Procedure".

NO >> INSPECTION END

Diagnosis Procedure

WARNING:
• Before servicing, turn ignition switch OFF, disconnect battery negative terminal, and wait at least 3 minutes or more. (To discharge backup capacitor.) • Never use unspecified tester or other measuring device.

1.CHECK HARNESS CONNECTOR

Check the harness connector.

Is the inspection result normal? YES >> GO TO 2.

NO >> Replace harness connector.

2.CHECK WIRING HARNESS

Check the wiring harness externals.

Is the inspection result normal? YES >> GO TO 3.

NO >> Replace wiring harness.

3.REPLACE SEAT BELT PRE-TENSIONER

1. Replace seat belt pre-tensioner RH. Refer to SR-32, "Removal and Installation".

2. Perform DTC confirmation procedure. Refer to SRC-69, "DTC Logic".

Is DTC detected? YES >> GO TO 4.

NO >> INSPECTION END

4.REPLACE AIR BAG DIAGNOSIS SENSOR UNIT

1. Replace air bag diagnosis sensor unit. Refer to SR-30, "Removal and Installation".

2. Perform DTC confirmation procedure. Refer to SRC-69, "DTC Logic".

Is DTC detected?

YES >> GO TO 1.

NO >> INSPECTION END

    B1082 seat belt Pre-tensioner RH
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.CHECK SELF-DIAG RESULT With CONSULT-III 1. Turn ignition switch ON. 2. Perform “Self Diagnostic Result” mode of “AIR BAG” using CONSU ...

    B1084 seat belt Pre-tensioner RH
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.CHECK SELF-DIAG RESULT With CONSULT-III 1. Turn ignition switch ON. 2. Perform “Self Diagnostic Result” mode of “AIR BAG” using CONSU ...

    Other materials:

    HR16DE : Inspection and Adjust
    INSPECTION Magnetic Switch Check • Before starting to check, disconnect the battery cable from the negative terminal. • Disconnect “M” terminal of starter motor. 1. Continuity test [between “S” terminal (A) and switch body] B : “B” terminal C : “M” terminal • Replace magnetic switch if co ...

    ACC warning does not operate
    Diagnosis Procedure 1.CHECK COMBINATION METER BUZZER Check combination meter buzzer. Refer to WCS-40, "Component Function Check". Is the inspection result normal? YES >> GO TO 2. NO >> Repair or replace the malfunctioning parts. 2.REPLACE BCM 1. Replace BCM. Ref ...

    Basic inspection
    DIAGNOSIS AND REPAIR WORKFLOW Work Flow DETAILED FLOW 1.INTERVIEW FROM THE CUSTOMER Clarify customer complaints before inspection. First of all, perform an interview utilizing STC-17, "Diagnostic Work Sheet" and reproduce symptoms as well as fully understand it. Ask customer about ...