Nissan Juke Service and Repair Manual : ASCD indicator

Component Function Check

1.CHECK ASCD INDICATOR FUNCTION

Check ASCD indicator under the following conditions.

Is the inspection result normal?


Is the inspection result normal? YES >> INSPECTION END

NO >> Go to EC-767, "Diagnosis Procedure".

Diagnosis Procedure

1.CHECK DTC

Check that DTC UXXXX is not displayed.

Is the inspection result normal? YES >> GO TO 2.

NO >> Perform trouble diagnosis for DTC UXXXX.

2.CHECK DTC WITH COMBINATION METER

Check DTC with combination meter. Refer to MWI-36, "DTC Index".

Is the inspection result normal? YES >> GO TO 3.

NO >> Repair or replace.

3.CHECK INTERMITTENT INCIDENT

Refer to GI-42, "Intermittent Incident".

Is the inspection result normal? YES >> Replace combination meter. Refer to MWI-69, "Exploded View".

NO >> Repair or replace.

    ASCD brake switch
    Component Function Check 1.CHECK ASCD BRAKE SWITCH FUNCTION With CONSULT-III 1. Turn ignition switch ON. 2. Select “ENGINE” using CONSULT-III. 3. Select “BRAKE SW1” in “DATA MONITOR” mode. 4. Ch ...

    ASCD main switch
    Component Function Check 1.CHECK ASCD MAIN SWITCH FUNCTION With CONSULT-III 1. Turn ignition switch ON. 2. Select “ENGINE” using CONSULT-III. 3. Select “MAIN SW” in “DATA MONITOR” mode. 4. Check ...

    Other materials:

    Cylinder Head
    VALVE DIMENSIONS VALVE GUIDE VALVE SEAT *1: Diameter made by intersection point of conic angles “α1” and “α2” *2: Diameter made by intersection point of conic angles “α2” and “α3” *3: Machining data VALVE SPRING ...

    Charging system preliminary inspection
    Inspection Procedure 1.CHECK BATTERY TERMINALS CONNECTION Check if battery terminals are clean and tight. Is the inspection result normal? YES >> GO TO 2. NO >> Repair battery terminals connection. 2.CHECK FUSE Check for blown fuse and fusible link. Is the inspection resu ...

    G sensor calibration
    Description TCM stores calibration data (inherent characteristic value) of G sensor to provide accurate control. Therefore, it is required to perform calibration of G sensor after the following work is performed. • Removal/installation or replacement of G sensor • Replacement of TCM Proce ...